Voltage Drop Calculator

Calculate voltage drop in volts and percent, minimum conductor size, maximum circuit length, and NEC 3% / 5% compliance for copper and aluminum conductors.

4.96 ★ Verified Ratings
236K+ Active Users
v4.3.0 Latest Version
15.6 MB Lightweight APK
Zero Cloud 100% On-Device
Professional Voltage Drop Suite

Key Features & Calculation Capabilities

A complete voltage drop and conductor sizing toolkit engineered for electricians, electrical engineers, contractors, and inspectors who need fast, accurate NEC compliance checks for branch circuits and feeders.

Core Calculation

Voltage Drop in Volts & Percent

Calculate voltage drop with VD = (2 × K × I × L) ÷ CM for single-phase and VD = (√3 × K × I × L) ÷ CM for three-phase, where K is 12.9 for copper and 21.2 for aluminum. Percent drop = (VD ÷ Source Voltage) × 100.

K = 12.9 Cu / 21.2 Al Single / Three-Phase
Code Compliance

NEC 3% Branch & 5% Total Checks

Compare results against the NEC 210.19(A) Informational Note No. 4 and 215.2(A)(1) Informational Note No. 2 recommendations: 3% maximum on a branch circuit and 5% maximum combined feeder plus branch circuit. The app flags PASS, WARNING, or FAIL for each limit.

3% Branch 5% Total
Sizing

Minimum Conductor Size Selector

Find the smallest AWG or kcmil conductor that keeps voltage drop within your target percentage, using circular mil values from 14 AWG (4,110 CM) through 1,000 kcmil. Results are cross-checked against NEC 310.16 ampacity so the selected size never undersizes protection.

14 AWG – 1000 kcmil NEC 310.16
Distance

Maximum Circuit Length Calculator

Reverse-solve the maximum one-way run length for a given conductor size, load, and allowable drop percentage. Essential for long runs to outbuildings, pumps, EV chargers, and remote panels where voltage drop — not ampacity — drives the wire size.

Max Run Length Long Runs / Feeders
Materials

Copper & Aluminum Support

Switch between copper and aluminum conductors with the correct K constant applied automatically. The app also supports AC and DC systems and lets you enter a power factor for accurate AC voltage drop on reactive loads such as motors and transformers.

Copper / Aluminum AC / DC / Power Factor
Reporting

Reports, NEC References & Export

Generate PDF calculation sheets showing inputs, formulas, voltage drop in volts and percent, compliance status, recommended conductor size, and the applicable NEC references. Export to CSV for project documentation. All calculations run offline on-device.

PDF / CSV Export Offline Reports